{"title":"PPM Oxygen Sensors","description":"","products":[{"product_id":"to2-1x-ppm-oxygen-sensor","title":"TO2-1x PPM Oxygen Sensor","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\n\u003cp\u003eThe TO2-1x PPM Oxygen Sensor delivers high accuracy, reliability, and linearity across its full measurement range.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.01 parts-per-million (ppm) up to 25.0%. For maximum life and performance, it is recommended for use in applications where oxygen levels are below 1000 ppm.\u003c\/p\u003e\n\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are recognized for their quality, performance, and exceptional value.\u003c\/p\u003e\n\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e✔ Ultra-low ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Electrochemical micro-fuel cell technology\u003c\/li\u003e\n\u003cli\u003e✔ Designed for trace oxygen monitoring\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e Micro-Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm – 10,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe TO2-1x is a competitive drop-in replacement for multiple oxygen sensors in the market. No modifications are required — simply remove the existing sensor and install the TO2-1x into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eTeledyne Analytical Inc.\u003c\/td\u003e\n\u003ctd\u003eB-2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Industries Inc. (Advanced Instruments)\u003c\/td\u003e\n\u003ctd\u003ePSR-12-223\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eBaker Hughes (Panametrics)\u003c\/td\u003e\n\u003ctd\u003eOX-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eBaker Hughes (Panametrics)\u003c\/td\u003e\n\u003ctd\u003eOX-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-1x-trace-oxygen-sensor-technical-data.pdf?v=1775622845\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":14321523523633,"sku":"1607663517","price":129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/TO2-1x_PPM_Oxygen_Sensor.png?v=1774366530"},{"product_id":"to2-133-ppm-oxygen-sensor","title":"TO2-133 PPM Oxygen Sensor","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\n\u003cp\u003eThe TO2-133 PPM Oxygen Sensor delivers high accuracy, reliability, and linearity across its full measurement range.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.01 parts-per-million (ppm) up to 25.0%. For maximum life and performance, it is recommended for use in applications where oxygen levels are below 1000 ppm.\u003c\/p\u003e\n\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are recognized for their quality, performance, and exceptional value.\u003c\/p\u003e\n\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e✔ Ultra-low ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Electrochemical micro-fuel cell technology\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for trace oxygen monitoring\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eElectrochemical Micro-Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm – 10,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe TO2-133 is a competitive drop-in replacement for multiple oxygen sensors in the market. No modifications are required — simply remove the existing sensor and install the TO2-133 into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Industries Inc. (Advanced Instruments)\u003c\/td\u003e\n\u003ctd\u003eGPR-12-333\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/TO2-133.pdf\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":14325491236913,"sku":"1607663514","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-133-trace-ppm-oxygen-sensor-fuel-cell..png?v=1775339276"},{"product_id":"to2-1xl-ppm-oxygen-sensor","title":"TO2-1xL PPM Oxygen Sensor","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\n\u003cp\u003eThe TO2-1xL PPM Oxygen Sensor delivers high accuracy, reliability, and linearity across its full measurement range.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.01 parts-per-million (ppm) up to 25.0%. For maximum life and performance, it is recommended for use in applications where oxygen levels are below 1000 ppm.\u003c\/p\u003e\n\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are recognized for their quality, performance, and exceptional value.\u003c\/p\u003e\n\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e✔ Ultra-low ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Electrochemical micro-fuel cell technology\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for trace oxygen monitoring\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eElectrochemical Micro-Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm – 10,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe TO2-1xL is a competitive drop-in replacement for oxygen sensors in the market. No modifications are required — simply remove the existing sensor and install the TO2-1xL into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eTeledyne Analytical Inc.\u003c\/td\u003e\n\u003ctd\u003eB-2CXL\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-1xl-long-life-trace-oxygen-sensor-datasheet.pdf?v=1775622504\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":14325496971313,"sku":"1607663518","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-1xl-extended-life-trace-oxygen-sensor-ppm..png?v=1775339228"},{"product_id":"to2-19-hybrid-ppm-oxygen-sensor","title":"TO2-19 Hybrid PPM Oxygen Sensor","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\n\u003cp\u003eThe TO2-19 Hybrid PPM Oxygen Sensor delivers high accuracy, reliability, and linearity across its full measurement range.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor is capable of measuring oxygen from 45 parts-per-million (ppm) up to 25.0%. A unique feature of this sensor is its ability to be exposed to ambient air when not in use while still maintaining a fast and accurate response down to low ppm levels. This makes it ideal for applications such as 3D metal printing and welding.\u003c\/p\u003e\n\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are recognized for their quality, performance, and exceptional value.\u003c\/p\u003e\n\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e✔ Hybrid ppm + percent oxygen measurement\u003c\/li\u003e\n\u003cli\u003e✔ Fast response even after ambient air exposure\u003c\/li\u003e\n\u003cli\u003e✔ Ideal for welding and 3D metal printing applications\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eMicro-Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 1000 ppm – 25.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-19-trace-oxygen-sensor-datasheet-buy-sso2.pdf?v=1775622351\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":14325503787057,"sku":"1607663515","price":129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-19-trace-oxygen-sensor-ppm-fuel-cell..png?v=1775339334"},{"product_id":"to2-1l-ppm-oxygen-sensor","title":"TO2-1L PPM Oxygen Sensor","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\n\u003cp\u003eThe TO2-1L PPM Oxygen Sensor delivers high accuracy, reliability, and linearity across its full measurement range.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.01 parts-per-million (ppm) up to 25.0%. For maximum life and performance, it is recommended for use in applications where oxygen levels are below 1000 ppm.\u003c\/p\u003e\n\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are recognized for their quality, performance, and exceptional value.\u003c\/p\u003e\n\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e✔ Ultra-low ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Electrochemical micro-fuel cell technology\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for trace oxygen monitoring\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eMicro-Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm – 10,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe TO2-1L is a competitive drop-in replacement for multiple oxygen sensors currently available in the market. No modifications are required — simply remove the existing sensor and install the TO2-1L into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eTeledyne Analytical Inc.\u003c\/td\u003e\n\u003ctd\u003eL-2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Industries Inc. (Advanced Instruments)\u003c\/td\u003e\n\u003ctd\u003ePSR-12-223-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-1l-trace-oxygen-sensor-technical-datasheet.pdf?v=1775622939\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":14325505785905,"sku":"1607663516","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-1l-long-life-trace-oxygen-sensor-ppm-fuel-cell..png?v=1775339664"},{"product_id":"to2-it-ppm-oxygen-sensor","title":"TO2-IT PPM Oxygen Sensor","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003eThe TO2-IT PPM Oxygen Sensor provides high levels of accuracy, reliability, and linearity throughout its measurement range.\u003c\/p\u003e\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.01 parts-per-million up to 25.0%. For maximum life and performance, it is recommended for use when monitoring oxygen below 1000 ppm.\u003c\/p\u003e\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are known for their quality, performance, and exceptional value.\u003c\/p\u003e\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e✔ Trace ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for acid gas environments (CO₂ \/ natural gas)\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Micro fuel cell electrochemical technology\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eMicro Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 10 PPM (Min) \/ 0 - 10,000 PPM (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TO2-IT is a competitive drop-in replacement for multiple oxygen sensors in the market. No modifications are required — simply remove the existing sensor and install the TO2-IT into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTeledyne Analytical Inc.\u003c\/td\u003e\n\u003ctd\u003eInstaTrace (B71875)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-it-trace-oxygen-sensor-datasheet-technical-specs.pdf?v=1775622888\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":14325510406193,"sku":"1607663523","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-1t-trace-oxygen-sensor-ppm-fuel-cell..png?v=1775339396"},{"product_id":"to2-2x-ppm-oxygen-sensor-for-use-in-co2","title":"TO2-2x PPM Oxygen Sensor (For use in CO2)","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003eThe TO2-2x PPM Oxygen Sensor provides high levels of accuracy, reliability, and linearity throughout its measurement range.\u003c\/p\u003e\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.01 parts-per-million up to 25.0%. For maximum life and performance, it is recommended for use when monitoring oxygen below 1000 ppm.\u003c\/p\u003e\n\u003cp\u003eThe TO2-2x series oxygen sensor is designed for use in acid gas streams such as CO₂ or natural gas background gas.\u003c\/p\u003e\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are known for their quality, performance, and exceptional value.\u003c\/p\u003e\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e✔ Trace ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for acid gas environments (CO₂ \/ natural gas)\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Micro fuel cell electrochemical technology\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eMicro Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 10 PPM (Min) \/ 0 - 10,000 PPM (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TO2-2x is a competitive drop-in replacement for multiple oxygen sensors in the market. No modifications are required — simply remove the existing sensor and install the TO2-2x into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTeledyne Analytical Inc.\u003c\/td\u003e\n\u003ctd\u003eA-2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Industries Inc. (Advanced Instruments)\u003c\/td\u003e\n\u003ctd\u003eXLT-12-123\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-2x-series-trace-oxygen-sensor-datasheet.pdf?v=1775622621\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":14325535834161,"sku":"1607663522","price":135.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-2x-trace-oxygen-sensor-acid-gas-resistant..png?v=1775339472"},{"product_id":"to2-233-ppm-oxygen-sensor-for-use-in-co2","title":"TO2-233 PPM Oxygen Sensor (For use in CO2)","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\n\u003cp\u003eThe TO2-233 PPM Oxygen Sensor delivers high accuracy, reliability, and linearity across its full measurement range.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.01 parts-per-million (ppm) up to 25.0%. For maximum life and performance, it is recommended for use in applications where oxygen levels are below 1000 ppm.\u003c\/p\u003e\n\n\u003cp\u003eThis TO2-233 series oxygen sensor is designed for use in acid gas streams such as CO₂ or natural gas background gas.\u003c\/p\u003e\n\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are recognized for their quality, performance, and exceptional value.\u003c\/p\u003e\n\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e✔ Trace ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for acid gas environments (CO₂ \/ natural gas)\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Micro fuel cell electrochemical technology\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eMicro-Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm – 10,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe TO2-233 is a competitive drop-in replacement for multiple oxygen sensors in the market. No modifications are required — simply remove the existing sensor and install the TO2-233 into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Industries Inc. (Advanced Instruments)\u003c\/td\u003e\n\u003ctd\u003eXLT-12-333\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-233-trace-oxygen-sensor-datasheet.pdf?v=1775622259\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":14325545435185,"sku":"1607663519","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-233-trace-ppm-oxygen-sensor-industrial-fuel-cell.png?v=1775339600"},{"product_id":"to2-238-ppm-oxygen-sensor-h2s-resistant","title":"TO2-238 PPM Oxygen Sensor (H2S Resistant)","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003eThe TO2-238 PPM Oxygen Sensor provides high levels of accuracy, reliability, and linearity throughout its measurement range.\u003c\/p\u003e\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.01 parts-per-million up to 25.0%. For maximum life and performance, it is recommended for applications where oxygen levels are below 1000 ppm.\u003c\/p\u003e\n\u003cp\u003eThe TO2-238 series oxygen sensor is designed for use in acid gas streams such as CO₂ or natural gas background gas environments.\u003c\/p\u003e\n\u003cp\u003eIt is also suitable for natural gas applications where H₂S gas is up to 500 ppm.\u003c\/p\u003e\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are known for quality, performance, and value.\u003c\/p\u003e\n\u003cp\u003eThese sensors operate under principles similar to those disclosed in US Patent Nos. 3,429,796 and 3,767,552.\u003c\/p\u003e\n\u003cp\u003eWhile minor modifications in dimensions, connections, and packaging may vary performance characteristics, the core operating principle remains the same across comparable sensors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e✔ Trace ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for acid gas environments (CO₂ \/ natural gas)\u003c\/li\u003e\n\u003cli\u003e✔ Suitable for H₂S environments up to 500 ppm\u003c\/li\u003e\n\u003cli\u003e✔ Micro fuel cell electrochemical technology\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eMicro Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 10 PPM (Min) \/ 0 - 10,000 PPM (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TO2-238 is a competitive drop-in replacement for multiple oxygen sensors in the market. No modifications are required — simply remove the existing sensor and install the TO2-238 into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced Micro Instruments\u003c\/td\u003e\n\u003ctd\u003eT-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-238-trace-oxygen-sensor-technical-datasheet.pdf?v=1775622107\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":14325552087089,"sku":"1607663521","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-238-trace-ppm-oxygen-sensor-industrial-fuel-cell..png?v=1775340004"},{"product_id":"to2-it-a-ppm-oxygen-sensor-for-use-in-co2","title":"TO2-IT-A PPM Oxygen Sensor (For use in CO2)","description":"\u003ch5\u003eOverview\u003c\/h5\u003e\n\u003cp\u003eThe TO2-IT-A PPM Oxygen Sensor \u003cspan\u003eprovides high levels of accuracy, reliability and linearity throughout its measurement ranges. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe sensor is capable of measuring oxygen from 0.01 parts-per-million up to 25.0%.  For maximum life and performance, we recommend to use it when monitoring oxygen \u0026lt; 1000 ppm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eThe TO2-IT-A series oxygen sensor is designed for us in acid gas streams such as a CO2 or natural gas background gas.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSouthland Sensing Ltd.'s direct fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are known for their quality, performance and exceptional value. \u003c\/p\u003e\n\u003cp\u003eSouthland Sensing Ltd. designs and manufactures oxygen sensors that have the same principle of operation as disclosed in US Patent Nos. 3,429,796 and 3,767,552. \u003c\/p\u003e\n\u003cp\u003eThe oxygen sensors operate under the same principles as those currently being marketed by other manufacturers. \u003c\/p\u003e\n\u003cp\u003eVarying performance advantages to the SSO2 sensors can be attributed to minor modifications in dimensions, connections, and packaging. However, the principle of operation and the basic components remain the same.\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003ctable style=\"width: 100%;\" class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Technology:\u003c\/td\u003e\n\u003ctd\u003eMicro Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\nMeasuring Range:\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\n0 - 10 PPM (Min)\u003cbr\u003e0 - 10000 PPM (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\nAccuracy Full Scale:\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\n+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\nOperating Temp:\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\n0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\nExpected Life:\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\n20 - 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWarranty:\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12 Months\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch5\u003eCross Reference\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TO2-IT-A is a competitive drop-in replacement for a variety of brands in the market.  The TO2-IT-A is a complete drop in replacement, no modifications are needed.  Simply remove your old sensor and re-install the new TO2-IT-A Trace Oxygen Sensor in your analyzer (similar to replacing a battery in a flashlight):\u003c\/p\u003e\n\u003ctable style=\"width: 100%;\" class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 350px;\"\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\nCompetitor\u003c\/td\u003e\n\u003ctd style=\"width: 178px;\"\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\nPart Number                   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 350px;\"\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cspan\u003eTeledyne Analytical Inc. \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 178px;\"\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\nInstaTrace (B73016)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownload\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/TO2-IT-A.pdf\" title=\"TO2-IT-A PPM Oxygen Sensor (For use in CO2) Product Brochure\" rel=\"noopener\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e to download the PDF.\u003c\/p\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":14325650227249,"sku":"1607663524","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-1t-a-trace-oxygen-sensor-acid-resistant-ppm..png?v=1775340166"},{"product_id":"to2-it-xl-ppm-oxygen-sensor","title":"TO2-IT-XL PPM Oxygen Sensor","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003eThe TO2-IT-XL PPM Oxygen Sensor provides high levels of accuracy, reliability, and linearity throughout its measurement range.\u003c\/p\u003e\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.01 parts-per-million up to 25.0%. For maximum life and performance, it is recommended for use when monitoring oxygen below 1000 ppm.\u003c\/p\u003e\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are known for their quality, performance, and exceptional value.\u003c\/p\u003e\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e✔ Trace ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for acid gas environments (CO₂ \/ natural gas)\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Micro fuel cell electrochemical technology\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eMicro Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 1 PPM (Min) \/ 0 - 10,000 PPM (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TO2-IT-XL is a competitive drop-in replacement for multiple oxygen sensors in the market. No modifications are required — simply remove the existing sensor and install the TO2-IT-XL into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTeledyne Analytical Inc.\u003c\/td\u003e\n\u003ctd\u003eB73592 (Insta Trace XL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-it-xl-trace-oxygen-sensor-datasheet.pdf?v=1775622799\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":40539045593137,"sku":"1607663518","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-it-xl-long-life-trace-oxygen-sensor..png?v=1775337107"},{"product_id":"to2-133-ppm-oxygen-sensor-copy","title":"TO2-13M PPM Oxygen Sensor","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\n\u003cp\u003eThe TO2-13M PPM Oxygen Sensor delivers high accuracy, reliability, and linearity across its full measurement range.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.01 parts-per-million (ppm) up to 25.0%. For maximum life and performance, it is recommended for use in applications where oxygen levels are below 1000 ppm.\u003c\/p\u003e\n\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are recognized for their quality, performance, and exceptional value.\u003c\/p\u003e\n\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e✔ Ultra-low ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Electrochemical micro-fuel cell technology\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for trace oxygen monitoring\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eElectrochemical Micro-Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm – 10,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe TO2-13M is a competitive drop-in replacement for multiple oxygen sensors available in the market. No modifications are required — simply remove the existing sensor and install the TO2-13M into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Industries Inc. (Advanced Instruments)\u003c\/td\u003e\n\u003ctd\u003eGPR-12-333-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-133-trace-oxygen-sensor-datasheet-buy-sso2.pdf?v=1775622046\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":40882789089329,"sku":null,"price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-13m-threaded-trace-oxygen-sensor-replacement..png?v=1775338088"},{"product_id":"to2-1m-ppm-oxygen-sensor","title":"TO2-1M PPM Oxygen Sensor","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\n\u003cp\u003eThe TO2-1M PPM Oxygen Sensor delivers high accuracy, reliability, and linearity across its full measurement range.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.1 parts-per-million (ppm) up to 25.0%. For maximum life and performance, it is recommended for use in applications where oxygen levels are below 1000 ppm.\u003c\/p\u003e\n\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are recognized for their quality, performance, and exceptional value.\u003c\/p\u003e\n\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e✔ Ultra-low ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Electrochemical micro-fuel cell technology\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for trace oxygen monitoring\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e Micro-Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm – 10,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe TO2-1M is a competitive drop-in replacement for multiple oxygen sensors in the market. No modifications are required — simply remove the existing sensor and install the TO2-1M into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Industries Inc. (Advanced Instruments)\u003c\/td\u003e\n\u003ctd\u003eGPR-12-100-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/sso2.com\/wp-content\/uploads\/2020\/11\/to2-133_2020_november_12.pdf\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":40882805145649,"sku":null,"price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-1m-trace-ppm-oxygen-sensor-threaded-base..png?v=1775338207"},{"product_id":"to2-2m-ppm-oxygen-sensor-for-use-in-co2","title":"TO2-2M PPM Oxygen Sensor (For use in CO2)","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003eThe TO2-2M PPM Oxygen Sensor provides high levels of accuracy, reliability, and linearity throughout its measurement range.\u003c\/p\u003e\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.1 parts-per-million up to 25.0%. For maximum life and performance, it is recommended for use when monitoring oxygen below 1000 ppm.\u003c\/p\u003e\n\u003cp\u003eThe TO2-2M series oxygen sensor is designed for use in acid gas streams such as CO₂ or natural gas background gas.\u003c\/p\u003e\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are known for their quality, performance, and exceptional value.\u003c\/p\u003e\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e✔ Trace ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for acid gas environments (CO₂ \/ natural gas)\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Micro fuel cell electrochemical technology\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eMicro Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 10 PPM (Min) \/ 0 - 10,000 PPM (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TO2-2M is a competitive drop-in replacement for multiple oxygen sensors in the market. No modifications are required — simply remove the existing sensor and install the TO2-2M into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Industries Inc. (Advanced Instruments)\u003c\/td\u003e\n\u003ctd\u003eXLT-12-100-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/TO2-2M.pdf\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":40882807636017,"sku":null,"price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-2m-threaded-trace-ppm-oxygen-sensor..png?v=1775338266"},{"product_id":"to2-23m-ppm-oxygen-sensor-for-use-in-co2","title":"TO2-23M PPM Oxygen Sensor (For use in CO2)","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003eThe TO2-23M PPM Oxygen Sensor provides high levels of accuracy, reliability, and linearity throughout its measurement range.\u003c\/p\u003e\n\u003cp\u003eThe sensor is capable of measuring oxygen from 0.1 parts-per-million up to 25.0%. For maximum life and performance, it is recommended for use when monitoring oxygen below 1000 ppm.\u003c\/p\u003e\n\u003cp\u003eThe TO2-23M series oxygen sensor is designed for use in acid gas streams such as CO₂ or natural gas background gas.\u003c\/p\u003e\n\u003cp\u003eSouthland Sensing Ltd.'s direct-fit replacement electrochemical galvanic \"micro fuel cell\" oxygen sensors are known for their quality, performance, and exceptional value.\u003c\/p\u003e\n\u003cp\u003eThese sensors operate using the same electrochemical principles disclosed in US Patent Nos. 3,429,796 and 3,767,552 and follow the same operating concepts used by other manufacturers in the industry.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e✔ Trace ppm oxygen measurement capability\u003c\/li\u003e\n\u003cli\u003e✔ Optimized for acid gas environments (CO₂ \/ natural gas)\u003c\/li\u003e\n\u003cli\u003e✔ High accuracy and stability\u003c\/li\u003e\n\u003cli\u003e✔ Micro fuel cell electrochemical technology\u003c\/li\u003e\n\u003cli\u003e✔ Backed by our 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003eMicro Fuel Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 1 PPM (Min) \/ 0 - 10,000 PPM (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 – 25 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eCross Reference\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Fit Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TO2-23M is a competitive drop-in replacement for multiple oxygen sensors in the market. No modifications are required — simply remove the existing sensor and install the TO2-23M into your analyzer, similar to replacing a battery.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:60%;\"\u003e\u003cstrong\u003eCompetitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width:40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Industries Inc. (Advanced Instruments)\u003c\/td\u003e\n\u003ctd\u003eXLT-12-333-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4\u003eDownload\u003c\/h4\u003e\n\u003cdiv style=\"margin-top:10px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/TO2-23M.pdf\" style=\"display:inline-block;background:#0f4c75;color:#fff;padding:12px 20px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003e\nDownload Technical Datasheet\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Southland Sensing Ltd.","offers":[{"title":"Default Title","offer_id":40882885263409,"sku":null,"price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/5102\/4689\/files\/to2-23m-trace-ppm-oxygen-sensor-industrial-gas-analysis..png?v=1775343845"}],"url":"https:\/\/www.buysso2.com\/collections\/ppm-oxygen-sensors.oembed","provider":"buysso2.com","version":"1.0","type":"link"}